Hicem Plain & Designer Tiles

Ramco Hicem Fibre Cement Tiles offer excellent choices for grid false ceilings laid through an exposed grid system. These tiles come in different textures - Marina, Valley View and Cedar which increase the aesthetic ambience of your interiors. Hicem tiles offer superior thermal insulation properties and help you minimize air-conditioning power consumption.

Marina
Valley View
Cedar

PROPERTIES

  • ... Fire Resistant

    COMBUSTIBILITY

    Hicem Tiles are non-combustible as per BS: 476: Part-4-1970.

    IGNITABILITY

    Hicem Tiles are not ignitable, conform to Class as per BS: 476: Part-5-1979.

    FIRE PROPAGATION INDEX

    Fire Propagation Index I= 0.7, which is the best in Class as per BS: 476: Part-6-1989.

    SURFACE SPREAD OF FLAME

    Hicem Tiles conform to Class I as per BS: 476: Part-7-1997, indicating it does not allow spread of flame.

  • ... Water Resistant

    Hicem Tiles are water-resistant and are not affected even after soaking in water for 24 hours

  • ... Vermin & Termite
    Resistant

    Hicem Tiles are made mostly of inorganic minerals and hence are Vermin & Termite Resistant.

  • ... 100% Asbestos Free

    Hicem Tiles is manufactured using cement, cellulose fibres with special additives and do not contain Asbestos.

APPLICATIONS

Offices

Residences

Commercial Units

Industrial Units

SPECIFICATIONS

PROPERTIES UNIT STANDARD VALUES
Thickness mm IS 14862:2000 4 and 6
Nominal Length mm IS 14862:2000 595, 610, 1195, 1220
Nominal Width mm IS 14862:2000 595, 610, 595
Apparent Density (Dry) Kg/m3 IS 14862:2000 1200
Water Absorption % - 38
Modulus of Rupture (EMC) MPa IS 14862:2000 14 - Parallel, 8 - Perpendicular
Alkalinity pΗ - 8 – 9
Combustibility - BS 476:Part 4:1970 Non-combustible
Ignitability - BS 476:Part 5:1979 ‘P’ Not Easily Ignitable
Fire Propagation Index - BS 476:Part 6:1989 I - 0.7
Surface Spread of Flame - BS 476:Part 7:1997 Class – 1
Water Impermeability - IS 14862:2000 No Leakage
Freeze Thaw Test - IS 14862:2000 Passes 100 Cycles (2 hours cycle)
Warm Water - IS 14862:2000 Passes 56 days
Soak Dry - IS 14862:2000 Passes 50 Cycles (2 hours cycle)
Heat Rain - IS 14862:2000 Passes 50 Cycles (2.5 hours cycle)
Biological - - No fungus growth or termite attack